Output Function 3 - Limit Monitoring Left / Right

Scroll Prev Top Next More

Activation and deactivation via position condition. The pulse duration is defined via a position window (right/left position distance).

Subindex

Type

Access type

Description

02h

integer32

R/W

Function:
1 = right limit active: Limit monitoring positive direction
2 = left limit active: Limit monitoring negative direction
3 = both: Both limit monitoring active

03h

integer32

R/W

right position: Absolute position for limit monitoring right / positive

04h

integer32

R/W

left position: Absolute position for limit monitoring left / negative

05h

integer32

R/W

right position distance: Pulse width limit monitoring right / positive

06h

integer32

R/W

left position distance: Pulse width of limit monitoring left / negative

Configuration example

Configuration

Explanation

3611h.01h = 3
3611h.02h = 1

3611h.03h = <Limit absolute>
3611h.05h = <pulse width>

Travel in positive direction, OUT1 state depending on position:

                 OUT1=high____________________________

                         |                            |

 OUT1=low________________|                            |_________

                     3611h.03h               3611h.03h + 3611h.05h