Each digital input can trigger one of the input functions described below.

You can set for each input:

Which function is triggered on a rising edge (input changes from 0V 'Low' to 24V 'High').

Which function is triggered on a falling edge (input changes from 24V 'High' to 0V 'Low').

The functions are set via the following parameter objects:

Object 3511h - Input Function / Reaction to IN1
Object 3512h - Input Function / Reaction to IN2
Object 3513h - Input Function / Reaction to IN3
...
Object 3518h - Input Function / Reaction to IN8
Object 3519h - Input Function / Reaction to IN9
Object 351Ah - Input Function / Reaction to IN10

NOTE: Each MovingCap Ethernet drive provides the complete object range for IN1 - IN10, even if the motor - depending on the model and options - offers fewer than 10 digital inputs as an electrical interface (see connections). The additional objects can be used to store further drive profiles, which can be started via object 3510.01h Virtual Inputs or object 3510h.02h Input Fct Command.